China Gold Supplier for China 20-2000kw Generating Set Electric Power Diesel Generator Powered by Cummins Engine with Stamford Alternator OEM Factory
Adhering to your principle of “quality, assistance, performance and growth”, we’ve obtained trusts and praises from domestic and worldwide client for China Gold Supplier for China 20-2000kw Generating Set Electric Power Diesel Generator Powered by Cummins Engine with Stamford Alternator OEM Factory, With our rules of ” small business status, partner trust and mutual benefit”, welcome all of you to definitely get the job done jointly , mature jointly.
Adhering to your principle of “quality, assistance, performance and growth”, we’ve obtained trusts and praises from domestic and worldwide client for China Generator Set, Diesel Generator Set, we’ve got complete material production line, assembling line , quality control system, and the most importantly, we have many patents technology and experienced technical&production team, specialist sales service team. With all these advantages, we are gonna create”the reputable international brand of nylon monofilaments”, and spreading our goods to every corner of the world. We have been keep moving and try our best to serve our customers.
Weichai Deutz 226B series WD615/WD618/WP12 series diesel geberator sets. Adopt 226 series diesel engine product by the joint venture with German DEUTZ. Deutz generator is with reliable performance, good quality, small volume, low fuel consumption. Power range is 20KW-500KW.
Product Features:
1. Procious structure and design, using and maintance conveniently.
2. Adaptability to environment, high reliablity, wide application.
3.Low shaking, low noise, low temperature and good starting.
Genset Technical Parameters:
Generator Model |
Diesel Generator |
Diesel Engine |
Alternator |
Size L×W×H (mm) |
Weight (KG) |
|||
Prime Power (KW/KVA) |
Standby Power |
Model |
Power (KW) |
Model |
Power (KW) |
|||
BC-20KW |
20/25 |
22/27.5 |
D226B-3D |
30 |
PI144E |
20/25 |
1650*650*1400 |
600 |
BC-25KW |
25/31.5 |
27.5/34.4 |
D226B-3D |
30 |
PI144G |
25/31.5 |
1650*650*1400 |
700 |
BC-30KW |
30/37.5 |
33/41.25 |
WP4D66E200 |
60 |
PI144J |
30/37.5 |
1650*650*1400 |
700 |
BC-34KW |
34/42.5 |
37.4/46.8 |
WP4D66E200 |
60 |
PI144K |
34/42.5 |
1650*650*1400 |
700 |
BC-40KW |
40/50 |
44/55 |
WP4D66E200 |
60 |
UCI224D |
40/50 |
1650*650*1400 |
750 |
BC-50KW |
50/62.5 |
55/68.75 |
WP4D66E200 |
60 |
UCI224E |
50/62.5 |
1900*650*1400 |
800 |
BC-60KW |
60/75 |
66/82.5 |
WP4D100E200 |
90 |
UCI224F |
60/75 |
2700*820*1500 |
1000 |
BC-80KW |
80/100 |
88/110 |
WP4D100E200 |
90 |
UCI274C |
80/100 |
2700*820*1500 |
1000 |
BC-100KW |
100/125 |
110/137.5 |
WP6D132E200 |
120 |
UCI274D |
100/125 |
2700*820*1500 |
1300 |
BC-120KW |
120/150 |
132/165 |
WP6D132E200 |
120 |
UCI274F |
120/150 |
2700*820*1500 |
1300 |
BC-160KW |
160/200 |
176/220 |
BF6M1015-LAGA |
208 |
UCI274H |
160/200 |
2710*1130*1710 |
2600 |
BC-180KW |
180/225 |
198/247.5 |
BF6M1015-LAGA |
208 |
UCI274J |
180/225 |
2710*1130*1710 |
2650 |
BC-200KW |
200/250 |
220/275 |
BF6M1015C-LAG1A |
228 |
UCI274K |
200/250 |
2710*1130*1710 |
2800 |
BC-240KW |
240/300 |
264/330 |
BF6M1015C-LAG3A |
282 |
HCI444D |
240/300 |
3020*1130*1710 |
3200 |
BC-280KW |
280/350 |
308/385 |
BF6M1015C-LAG34 |
310 |
HCI444E |
280/350 |
3060*1135*1710 |
3250 |
BC-300KW |
300/375 |
330/412.5 |
BF6M1015CP-LAG |
328 |
HCI444FS |
300/375 |
3100*1135*1710 |
3300 |
BC-320KW |
320/400 |
350/400 |
BF8M1015C-LAG1A |
388 |
HCI444FS |
320/400 |
3260*1135*1710 |
3400 |
BC-400KW |
400/500 |
450/563 |
TBD234V12-1A |
448 |
HCI544C |
400/500 |
4170*1320*2015 |
5300 |
BC-500KW |
500/625 |
500/688 |
TBD640BL6-2A |
564 |
HCI544FS |
500/625 |
4526*1505*2156 |
5600 |
Note:
The above information of list is 50HZ,COSØ=0.8, 400/230V 3P 4W.60Hz generators can be customized.
Prime power: the maximum power of continuous work for 12 hours in the fluctuant load. In case continuous work for 24 hours, the average running power can not be more than the 80% of prime power.
Standby power: the maximum running power of generator set, in the fluctuant load and emergency situations, the running time limit of generator set can be not more than 500 hours in one year, the continuous running time can be not more than 2 hours for one time, forbid overload running.